Stay strands is one of SwedWire’s specialities. The strands are manufactured in many different standards, IEC, DIN, BS, ASTM, NS, SS etc. and with zinc layers up to 70 µm. If desired, the strands can be delivered greased with different types of lubricants.
If the customer has demands on low residual elongation we have the possibility to prestress the strands and measure and certify the modulus of elasticity. If desired the strands can also be delivered in exact lengths with casted or pressed end fittings according to valid specification.
| Construction | 1×7 | 1×19 | 1×37 | 1×61 |
| Wire dimension (d) mm | 1,50-4,40 | 1,50-4,40 | 1,50-4,40 | 1,50-4,40 |
| Strand dimension mm | 3 × d | 5 × d | 7 × d | 9 × d |
| Max strand dimension | 13 mm | 22 mm | 31 mm | 40 mm |
| Tensile strength (Rm) N/mm² | 600-1700 | 600-1700 | 600-1700 | 600-1700 |
| Area of steel mm² | 5,50 × d² | 14,92 × d² | 29,06 × d² | 47,91 × d² |
| Min breaking load N/mm² | 5,22 × d² × Rm | 14,2 × d² × Rm | 27,6 × d² × Rm | 45,5 × d² × Rm |
| Weight kg/meter | 0,0432 × d² | 0,1183 × d² | 0,2304 × d² | 0,3808 × d² |
| Max weight in one length | 2 800 kg | 4 510 kg | 8 790 kg | 10 000 kg |
d = wire dimension (mm); Rm = tensile strength (N/mm²) The min breaking load is based on lay factor 0,95
Zinc corrosion according to BSK
| In the interior with a low degree of pollution | 0,5 – 0,8 µm/year |
| In areas with increased degree of air pollutions, in bigger cities, industrial cities or close to the coast | 0,8 – 2 µm/year |
| In areas with a high degree of aggressive air pollutions, i.e. close to chemical industries | 2 – 5 µm/year |
| In areas with permanent high humidity or salt water winds | 2 – 10 µm/year |
Min. zinc layer µm
| Wire dia mm | acc. to BS 443 | SwedWire single galvanized | SwedWire double galvanized |
| 2,0 | 31 | 36 | 65 |
| 2,5 | 33 | 38 | 68 |
| 3,0 | 34 | 39 | 70 |
| 3,5 | 36 | 40 | 71 |
| 4,0 | 37 | 41 | 72 |
Stay strands in stock
| Con-struction | Wire-diameter mm | Metallic area mm² | Strand-diameter mm | Tensile strength N/mm² | Lay factor | Min breaking load kN | Weight kg/1000 m | Lay | |
| 3 | 3 | 2,60 | 16 | 5,6 | 590 | 0,95 | 8,9 | 125 | Right |
| 3 | 3 | 4,60 | 50 | 9,9 | 590 | 0,95 | 28 | 391 | Right |
| 7 | 6/1 | 1,71 | 16 | 5,1 | 590 | 0,95 | 9,0 | 126 | Right |
| 7 | 6/1 | 2,12 | 25 | 6,4 | 590 | 0,95 | 14 | 194 | Right |
| 7 | 6/1 | 2,44 | 33 | 7,3 | 590 | 0,95 | 18 | 257 | Right |
| 7 | 6/1 | 3,08 | 52 | 9,2 | 590 | 0,95 | 29 | 410 | Right |
| 7 | 6/1 | 1,80 | 18 | 5,4 | 780 | 0,95 | 13 | 140 | Right |
| 7 | 6/1 | 2,30 | 29 | 6,9 | 780 | 0,95 | 22 | 229 | Right |
| 12 | 9/3 | 2,30 | 50 | 9,0 | 780 | 0,95 | 37 | 391 | Right |
| 7 | 6/1 | 1,71 | 16 | 5,1 | 1370 | 0,95 | 21 | 126 | Right |
| 7 | 6/1 | 1,80 | 18 | 5,4 | 1370 | 0,95 | 23 | 140 | Right |
| 7 | 6/1 | 2,12 | 25 | 6,4 | 1370 | 0,95 | 32 | 194 | Right |
| 7 | 6/1 | 2,30 | 29 | 6,9 | 1370 | 0,95 | 38 | 229 | Right |
| 7 | 6/1 | 2,44 | 33 | 7,3 | 1370 | 0,95 | 43 | 257 | Right |
| 7 | 6/1 | 2,55 | 36 | 7,7 | 1370 | 0,95 | 47 | 281 | Right |
| 7 | 6/1 | 3,08 | 52 | 9,2 | 1370 | 0,95 | 68 | 410 | Left |
| 7 | 6/1 | 3,52 | 68 | 10,6 | 1370 | 0,95 | 89 | 535 | Left |
| 7 | 6/1 | 4,02 | 89 | 12,1 | 1370 | 0,95 | 116 | 698 | Left |
| 7 | 6/1 | 4,36 | 105 | 13,1 | 1370 | 0,95 | 136 | 821 | Left |
| 12 | 9/3 | 1,80 | 30 | 7,1 | 1370 | 0,95 | 40 | 240 | Right |
| 12 | 9/3 | 2,30 | 50 | 9,0 | 1370 | 0,95 | 65 | 391 | Right |
| 19 | 12/6/1 | 1,80 | 48 | 9,0 | 1370 | 0,95 | 63 | 383 | Right |
| 19 | 12/6/1 | 2,15 | 69 | 10,8 | 1370 | 0,95 | 90 | 547 | Right |
| 19 | 12/6/1 | 2,55 | 97 | 12,8 | 1370 | 0,95 | 126 | 769 | Right |
| 19 | 12/6/1 | 3,00 | 135 | 15,0 | 1370 | 0,95 | 175 | 1060 | Right |
| 19 | 12/6/1 | 3,08 | 142 | 15,4 | 1370 | 0,95 | 184 | 1120 | Right |
| 19 | 12/6/1 | 3,52 | 185 | 17,6 | 1370 | 0,95 | 241 | 1470 | Right |
| 37 | 18/12/6/1 | 2,55 | 190 | 17,9 | 1370 | 0,95 | 246 | 1500 | Right |
| 37 | 18/12/6/1 | 3,00 | 260 | 21,0 | 1370 | 0,95 | 340 | 2070 | Right |